EMC

TUV Rheinland of North America, Inc. provides EMC consultation, testing and certification services to help manufacturers comply with domestic emissions requirements (FCC) and the EMC requirements of the European EMC Directive 2004/108/EC.


FCC Approval / NVLAP

TUV Rheinland of North America, Inc.'s EMC and Telecom Division test labs are accredited for specific test methods by the U.S. National Institute of Standards and Technology (NIST) under the National Voluntary Laboratory Accreditation Program (NVLAP). Testing facilities are located coast to coast. Please contact us to find the one best suited for you.

NVLAP accredits qualified laboratories that offer services in the various fields of testing and calibration. This accreditation allows TUV Rheinland of North America to greatly accelerate the FCC approval process in areas of EMC and telecommunications testing by having the ability to self-declare conformity to standards and bypass the FCC's case review process. This can save our information technology equipment (ITE) and telecom clients weeks or months of waiting.

Summary matrix of U.S. FCC and Industry Canada EMC Emissions requirements with reference links to rules and regulations.

EMC Capatilities

Tests can be performed to almost all Harmonized Product Family Standards and EU Directives. Standard Test reports are typically delivered within 24 hours of completion of testing for standard test.

Emissions

  • EN 55011
  • EN 55013 (specific devices)
  • EN 55022
  • EN 50366
  • EN 60601-1-2
  • FCC (CFR 47) Parts 15, 18, 90
    and others
  • NVLAP Lab Code 200111

Harmonics and Voltage Fluctuation

  • EN 61000-3-2/EN 60555-2
  • EN 61000-3-3/EN 60555-3

Immunity

  • EN 61000-4-2
  • EN 61000-4-3 (ENV50140)
  • EN 61000-4-4
  • EN 61000-4-5
  • EN 61000-4-6 (ENV50141)
  • EN 61000-4-8
  • EN 61000-4-11
  • EN 61000-4-12
  • EN 55020 (specific devices)
  • EN 55014-2 (EN 55104)

Chamber One

Semi-Anechoic Chamber
Newtown, CT


  • Size of shielded enclosure: 16 ft wide x 14 ft high x 26 ft long (4.9 m wide x 4.3 m high by 7.9 m long)
  • Entry: 48" x 84" 800 lbs maximum per unit, 1500 lbs maximum per system
  • Size to tips of absorber cones: 12 ft wide x 11 ft high x 20 ft long (3.7 m wide x 3.4 m high x 6.1 m long)
  • Antenna to EUT separation: 3 m
  • Turntable: 6 ft (2 m) diameter, 1500 lb. capacity
  • Standard field strength to 10 V/m @ 3 m. Higher field strengths for particular tests.

Chamber Two

Semi-Anechoic Chamber
Newtown, CT


  • Size of shielded enclosure: 14 ft wide x 12.6 ft high x 24 ft long
  • Entry: 48" x 96" 800 lbs maximum per system
  • Size to tips of absorber cones: 11 ft wide x 20.5 ft high x 21 ft long
  • Antenna to EUT separation: 3 m
  • Turntable: 4 ft diameter, 800 lb. capacity
  • Standard field strength to 10 V/m @ 3 m. Higher field strengths for particular tests.

10-Meter Anechoic Chamber and Lab

Santa Clara, CA


  • State-of-the-art 10 meter anechoic chamber.
  • 10-meter chamber allows TUV to perform tests on large equipment weighing up to 8,800 pouinds on its four-meter turntable.
  • Almost any configuration of power can be supplied for the test, including three-phase AC power up to 100A an 48 VDC up to 150A for worldwide EMC requirements such as FCC, VCCI, BSMI, CE Marking and CISPR11.

Raleigh, NC EMC Lab


Wireless

  • FCC Part 15, 68, and 90
  • Most Harmonized Standards under R&TTE directive for Europe
  • NEBS GR-1089
  • ETSI EN 300 386
  • RSS-210

Product Specific EMC Standards

  • FCC Part 15 and 18
  • Most Harmonized Standards under the EMC directive for Europe
  • Most Common Harmonized Standards
  • EN 55022
  • EN 61326
  • EN 50130-4
  • EN 50199
  • EN 61000-6-1
  • EN 61000-6-3
  • EN 61326
  • EN 13309:2000
  • VCCI
  • EN 55024
  • EN 55103
  • EN 50091-2
  • EN 50240
  • EN 61000-6-2
  • EN 61000-6-4
  • EN ISO 14982:1998
  • EN 12895:2000

Basic Standards (Emissions)

  • EN 55011
  • EN 55012
  • EN 55013
  • EN 55014-1
  • EN 55022
  • EN 61000-3-2
  • EN 61000-3-3

Basic Standards (Immunity)

  • EN 61000-4-2
  • EN 61000-4-3
  • EN 61000-4-4
  • EN 61000-4-5
  • EN 61000-4-6
  • EN 61000-4-8
  • EN 61000-4-11
  • EN 55014-2

Other Testing Capabilities

  • ANSI C12.1
  • SAE J Standards
  • RTCA DO-160
  • CAN/CSA-C108.4-M92
  • AS/NZS CISPR 12:2004
  • EN 60601-1-2

Open Area Test Site (OATS)

Newtown, CT


  • Ground plane size: approximately 32 ft x 68 ft
  • Groundplane roughness is within Rayleigh criteria specified in ANSI C63.7 for 3 and 10 m measurements at 1000 MHz
  • Antenna to EUT separation: 3 and 10 m
  • Structure: RF transparent fiberglass structure
  • Weather protected, heated and air conditioned
  • Turntable: 10 ft ( 3 m) diameter 2000 lb. (900 kg) capacity
  • Entry: 67"W x 92"H EUT 83"W x 90"H Support Equipment
  • 800 lbs/unit maximum, 1500 lbs max. per system

Mobile EMC Labs

East & West coasts


  • The mobile lab is designed as an independent, complete test facility to maximize efficiency and minimize customer down time. All mobile lab equipment is dedicated to mobile testing. We do not borrow or rent test equipment. Typical test and report takes three days.
  • Testing at your facility for heavy industrial equipment using EN 55011, EN 61000-6-2, 6-3 and EN 14982 as guidelines through the technical construction file method as described in section 10.2 of the EMC directive.
  • Competent body representative located in the U.S. TCF review & certificate processing in the most efficient manner.
  • 50hz 3 phase power provided up to 63 A per phase. Higher currents possible by arrangement.